    Welcome to the website of Baoji Zhongheng Instrument Co., Ltd. Tel:+86-917-3512881
    Differential pressure transmitter Single crystal silicon pressure transmitter Electromagnetic flowmeter Capacitive pressure transmitter High precision pressure transmitter Intelligent pressure switch Diffused silicon pressure transmitter Flow switch Intelligent pressure transfer controller Thermometer

    Pressure transmitter


    BXY6002 gauge pressure BXY6003

    Product code

     

    Overview

    Product quotationProduct consulting

    Product introduction

    BXY6002 Gage Pressure Transmitter

    BXY6003- Absolute Pressure Transmitter
    The BXY6002/3-gauge/absolute pressure transmitter is used to measure the liquid level, density, and pressure of liquids, gases, or vapors, and then convert them into 4-20mADC HART current signals for output. BXY6002/3 can also communicate with RST375 handheld terminals or RSM100 Modems for parameter setting, process monitoring, etc.
    Standard specifications
    (Calibrate the range based on the standard zero point, stainless steel 316L diaphragm, filled with silicone oil)
    1 Performance specifications
    Reference accuracy for range adjustment
    (Including linearity, backlash, and repeatability from zero)
    ± 0.075%
    If TD>10 (TD=maximum range/adjustment range), then it is:
    ± (0.0075 × TD)%
    Environmental temperature impact


    Range code

    -Total impact from 20 ℃ to 65 ℃

    B/L

    ±(0.30×TD+0.20)%×Span

    other

    ±(0.20×TD+0.10)%×Span

    Range code

    -40℃~-20℃和65℃~85℃

    Total impact amount

    B/L

    ±(0.30×TD+0.20)%×Span

    other

    ±(0.20×TD+0.10)%×Span

    Over range impact: ± 0.075% × Span
    Long term stability


    Range code

    influence quantity

    B/L

    ±0.2%×Span/1year

    other

    ±0.1%×Span/1year

    Power impact
    ± 0.001%/10V (12-42V DC), negligible
    2 Functional specifications
    Range and range (BXY6002 gauge pressure)


    Range/Range

    kPa

    bar

    B

    range

    0.6~6

    6~60mbar

    range

    -6~6

    -60~60mbar

    C

    range

    2~40

    0.02~0.4

    range

    -40~40

    -0.4~0.4

    D

    range

    2.5~250

    0.025~2.5

    range

    -100~250

    -1~2.5

    F

    range

    30~3000

    0.3~30

    range

    -100~3000

    -1~30

    G

    range

    0.1~10MPa

    1~100

    range

    -0.1~10MPa

    -1~100

    H

    range

    0.21~21 MPa

    2.1~210

    range

    -0.1~21 MPa

    -1~210

    I

    range

    0.4~40 MPa

    4~400

    range

    -0.1~40 MPa

    -1~400

    J

    range

    0.6~60 MPa

    6~600

    range

    -0.1~60 MPa

    -1~600


    Range and Range (BXY6003- Absolute Pressure)

    Range and Range

    kPa

    bar

    L

    Range

    2~40

    0.02~0.4

    Range

    0~40

    0~0.4

    M

    Range

    2.5~250

    0.025~2.5

    Range

    0~250

    0~2.5

    O

    Range

    30~3000

    0.3~30

    Range

    0~3000

    0~30

    Range limit
    Within the upper and lower limits of the range, it can be adjusted arbitrarily. It is recommended to select range codes with the lowest possible range ratio to optimize performance characteristics.
    Zero point setting
    The zero point and range can be adjusted to any value within the measurement range in the table, as long as the calibrated range is ≥ the minimum range
    Installation position impact
    The change in installation position parallel to the film surface will not cause zero drift. If the installation position changes by more than 90 ° to the film surface, there will be zero drift within the range of<0.25kPa for range C, and zero drift within the range of<0.15kPa for other ranges. All can be corrected by adjusting zero. No range impact.
    Output
    2-wire system, 4-20mADC, selectable for digital communication with HART output, with options for linear or square root output.
    Output signal limit: Imin=3.9mA, Imax=20.mA
    Alarm current
    Low alarm mode (minimum): 3.7 mA
    High alarm mode (maximum): 21 mA
    No alarm mode (hold): maintain the effective current value before the fault
    Alarm current standard setting: high alarm mode
    Response time
    The damping constant of the amplifier component is 0.1s; The sensor time constant is between 0.1 and 1.6 seconds, depending on the range and range ratio. The additional adjustable time constant is 0.1~60s.
    Preheating time:<15s
    Environmental temperature
    -40-85 ℃
    When equipped with LCD display and fluororubber sealing ring, -20~65 ℃
    Storage temperature/transportation temperature
    -50-85 ℃
    With LCD display: -40~85 ℃
    Pressure limit
    From vacuum to maximum range.
    Overload limit:


    Range

    6kPa

    (B)

    40kPa

    (C/L)

    250kPa

    (D/M)

    3MPa

    (F/O)

    Overload limit

    0.2MPa

    1MPa

    4MPa

    16MPa

    Range

    10MPa

    (G)

    21MPa

    (H)

    40MPa

    (I)

    60MPa

    (K)

    Overload limit

    20MPa

    50MPa

    50MPa

    70MPa

    Electromagnetic compatibility (EMC)
    Refer to the "Electromagnetic Compatibility Schedule" on the next page
    3 Installation
    Power supply and load conditions
    The power supply voltage is 24V, R ≤ (Us-12V)/Imax k Ω
    Where Imax=23 mA
    Maximum power supply voltage: 42VDC
    Minimum power supply voltage: 12VDC, 15VDC (backlight LCD display)
    Digital communication load range: 230~600 Ω
    Electrical connections
    M20X1.5 cable sealing buckle and wiring terminal are suitable for wires ranging from 0.5 to 2.5mm2.
    Process Connection
    Standard process connection: NPT 1/2 internal thread, can be converted into NPT 1/2, G1/2, and M20x1.5 external thread, KF16 vacuum interface.
    4 Physical specifications
    material quality
    Diaphragm: stainless steel 316L, Hastelloy C
    Process connection: stainless steel 316L
    Filling fluid: silicone oil
    Transmitter housing: aluminum alloy material, with epoxy resin sprayed on the surface
    Shell sealing ring: nitrile rubber (NBR)
    Nameplate: stainless steel 304
    Weight
    1.6kg (without LCD display, mounting bracket, process connection)
    Shell protection level
    IP67
    Electromagnetic Compatibility Schedule



    External dimension unit (mm)
    Horizontal piping connection method (side) Horizontal piping connection method (front)


    Wall mounted connection method Vertical piping connection method

    5 Electrical connection diagram

    Note: The quick interface function is equivalent to the signal terminal.
    6 Process Connection Instructions (Code 1)
    6.1 Standard Form (Code 1)
    D/M/F/G/H/I/K/O Range Interface Diagram B/C/L Range Interface Diagram


    6.2 Derived interface form
    1/2 inch NPT external thread (code 2) M20x1.5 external thread (code 3)






























    ?