911在线视福利|91污视频在线观看|97色在线视频观看香蕉|99精品在线播放观看

<center id="ebsxb"></center>

    <sub id="ebsxb"><ol id="ebsxb"></ol></sub>
    Welcome to the website of Baoji Zhongheng Instrument Co., Ltd. Tel:+86-917-3512881
    Differential pressure transmitter Single crystal silicon pressure transmitter Electromagnetic flowmeter Capacitive pressure transmitter High precision pressure transmitter Intelligent pressure switch Diffused silicon pressure transmitter Flow switch Intelligent pressure transfer controller Thermometer

    Liquid level transmitter


    BXY6001 Differential Pressure

    Product code

     

    Overview

    Product quotationProduct consulting

    Product introduction

    The thermal flow switch adopts precision electronic components widely used in aviation and automobiles, and its reliable and stable circuit design makes the flow signal more accurate and stable. Currently, it has been widely used in industries such as steel, metallurgy, pharmaceuticals, and chemical engineering
    The ZH-L2 thermal flow switch is an upgraded version of the ZH-L1 model, which not only has more prominent improvements in the signal processing of the flow switch probe, but also makes the HL-L2 software operation and control functions more powerful; Easy to operate and easy to install.

    The measuring principle of the ZH-L2 thermal flow switch is the same as that of the ZH-L1, and it is also designed based on the principle of heat exchange. The probe is equipped with a heating module and a heat sensing module, and the heat dissipation of the heating module is closely related to the flow rate of the measured fluid. If there is no medium flow in the pipeline, the signal received by the heat sensing circuit is a fixed value; When the fluid medium flows through the probe, the signal received by the thermal circuit changes with the flow rate of the medium. The thermal circuit converts the temperature difference signal between the heating module and the thermal module into an electrical signal, and the processor then converts it into signals such as PNP/NPN/4-20mA/relay for output.
    Gas liquid dual purpose, can be used for gas and hydraulic systems, circulating water, cutting fluid and lubricating oil cutoff monitoring, and pump idle protection.

    Range code


    minimum range

    maximum range

    Rated pressure (maximum)

    B

    1kPa

    6kPa

    Rated pressure of liquid level flange

    C

    4kPa

    40kPa

    D

    25kPa

    250kPa

    E

    200kPa

    2MPa

    Table 2 Comparison Table of the Relationship between Liquid Level Flange and Minimum Range

    Level flange

    Nominal diameter

    minimum range

    Flat type

    DN 50/2”

    10kPa

    DN 80/3”

    1kPa

    DN 4”

    1kPa

    plug-in

    DN 50/2”

    16kPa

    DN 80/2”

    1kPa

    DN 4”

    1kPa

    The minimum range of the differential pressure liquid level transmitter should be the larger value of the minimum range in Table 1 and Table 2. The adjusted range shall not be less than the minimum range. The maximum range of the liquid level transmitter should be the minimum of the maximum range of the transmitter body and the rated pressure of the liquid level flange.
    4 output signals
    2-wire system, 4-20mADC HART output, digital communication, with HART protocol loaded on 4-20mADC signal.
    Output signal limit: Imin=3.9mA, Imax=20.mA
    Alarm current (mode can be set)
    Low alarm mode (minimum): 3.7 mA
    High alarm mode (maximum): 21 mA
    No alarm mode (hold): maintain the effective current value before the fault
    Alarm current standard setting: high alarm mode
    5 Response time
    The damping constant of the amplifier component is 0.1s; The time constant of the sensor and liquid level flange is 0.2-2 seconds, depending on the range and range ratio. The additional adjustable time constant is 0.1~60s.
    6 General conditions
    6.1 Installation conditions
    The liquid level flange transmitter can be directly fixed in any position. The optimal state is to keep the process flange axis in a vertical position, and the positional deviation will result in a correctable zero offset. The electronic watch case can rotate up to 360 °, and the positioning screw can fix it in any position.
    6.2 Environmental conditions
    ambient temperature
    Minimum: depending on the filling fluid
    Maximum: 85 ℃
    When equipped with LCD display and fluororubber sealing ring, -20~65 ℃
    Storage temperature/transportation temperature
    Minimum: depending on the filling fluid
    Maximum: 85 ℃
    Relative humidity
    0-100%
    Impact resistance
    Acceleration: 50g
    Duration: 11ms
    Anti vibration
    2g to 500Hz
    Electromagnetic compatibility (EMC)
    See Table 3 "Electromagnetic Compatibility Schedule" on the next page
    6.3 Process Medium Limits
    Medium temperature limit: -30~180 ℃
    Transmitter body pressure limit
    From an absolute pressure of 3.5kPa to the rated pressure, the protective pressure can be greater than 1.5 times the rated pressure and applied to both sides of the transmitter.
    Rated pressure of liquid level flange
    ANSI standard: 150psi~600psi
    DIN standard: PN 1.6MPa~PN 10MPa
    Unidirectional overload limit
    The low pressure side is the rated pressure of the transmitter body, and the high pressure side is the rated pressure of the liquid level flange, which may cause adjustable zero drift.
    Weight: DN 50/2 "approximately 7-10kg; DN 80/3 "approximately 8-11kg; DN 4 "is approximately 9-12kg.
    Explosion proof performance
    NEPSI Flameproof License: Ex d Ⅱ C T6
    NEPSI Intrinsic Safety License: Ex ia IIC T4
    Permissible operating temperature: -40 ℃~65 ℃
    6.4 Power supply and load conditions
    The power supply voltage is 24V
    R ≤ (Us-12V)/Imax k Ω
    Where Imax=23 mA
    Maximum power supply voltage: 42VDC
    Minimum power supply voltage


    Serial Number

    Test items

    Basic standards

    Test conditions

    Performance Level

    1

    Radiated interference (shell)

    GB/T 9254-2008表5

    30MHz~1000MHz

    qualified

    2

    Conducted interference
    (DC power port)


    GB/T 9254-2008表1

    0.15MHz~30MHz

    qualified

    3

    Electrostatic discharge (ESD) immunity

    GB/T 17626.2-2006

    4kV(觸點(diǎn))

    8kV(空氣)

    B

    4

    Radio frequency electromagnetic field immunity

    GB/T 17626.3-2006

    10V/m (80MHz~1GHz)

    A

    5

    Power frequency magnetic field immunity

    GB/T 17626.8-2006

    30A/m

    A

    6

    Electrical fast transient pulse group immunity

    GB/T 17626.4-2008

    2kV(5/50ns,5kHz)

    B

    7

    Surge immunity

    GB/T 17626.5-2008

    1kV(Between lines)

    2kV(Between lines)(1.2us/50us)

    B

    8

    Immunity to conducted interference induced by radio frequency fields

    GB/T 17626.6-2008

    3V (150KHz~80MHz)

    A

    Note: (1) A performance level description: During testing, the performance is normal within the technical specification limits.
    (2) B performance level description: During testing, the function or performance is temporarily reduced or lost, but it can recover on its own, and the actual operating status, storage, and data remain unchanged.
    External dimension unit (mm)


    Table 4 Structural dimensions of liquid level flange

    Nominal diameter

    Rated pressure

    ΦD

    ΦK

    Φd1

    Φd2

    Φd3

    t

    b

    Required bolts

    plug-in

    Flat type

    number

    thread

    DN 50

    PN1.6/4MPa

    165

    125

    48.3

    57

    102

    3+0.5

    20

    4

    M16

    (Sealing surfaceDIN 2526E

    PN 6.4MPa

    18

    135

    48.3

    57

    102

    3+0.5

    26

    4

    M20

    (flangeDIN 2501)

    PN 10MPa

    195

    145

    48.3

    57

    102

    3+0.5

    28

    4

    M20

    DN 80

    PN1.6/4MPa

    200

    160

    76

    75

    138

    3+0.5

    24

    8

    M16

    (Sealing surface DIN 2526E type)

    PN 6.4MPa

    215

    170

    76

    75

    138

    3+0.5

    28

    8

    M20

    (Flange DIN 2501)

    PN 10MPa

    230

    180

    76

    75

    138

    3+0.5

    32

    8

    M24

    DN 2"
    (ANSI B 16.5 RF)

    150psi

    152.4

    120.6

    48.3

    57

    92.1

    3+0.5

    17.4

    4

    M18

    300psi

    165.1

    127.0

    48.3

    57

    92.1

    3+0.5

    20.6

    8

    M18

    600psi

    165.1

    127.0

    48.3

    57

    92.1

    6.35

    31.75

    8

    M18

    DN 3"
    (ANSI B 16.5 RF)

    150psi

    190.5

    152.4

    76

    75

    127

    3+0.5

    22.2

    4

    M16

    300psi

    209.5

    168.3

    76

    75

    127

    3+0.5

    27.0

    8

    M20

    600psi

    209.5

    168.3

    76

    75

    127

    6.35

    38.05

    8

    M20

    DN 4“

    150psi

    229

    191

    89

    89

    157

    3+0.5

    30

    8

    M18

    (ANSI B 16.5 RF)

    300psi

    255

    200

    89

    89

    157

    3+0.5

    32

    8

    M18

    Note: Users can choose to install bolts and nuts.
    7 Electrical connection diagram


    Note: The quick interface function is equivalent to the signal terminal.
    8. Instructions for Low Voltage End Process Connection










    ?