911在线视福利|91污视频在线观看|97色在线视频观看香蕉|99精品在线播放观看

<center id="ebsxb"></center>

    <sub id="ebsxb"><ol id="ebsxb"></ol></sub>
    Welcome to the website of Baoji Zhongheng Instrument Co., Ltd. Tel:+86-917-3512881
    Differential pressure transmitter Single crystal silicon pressure transmitter Electromagnetic flowmeter Capacitive pressure transmitter High precision pressure transmitter Intelligent pressure switch Diffused silicon pressure transmitter Flow switch Intelligent pressure transfer controller Thermometer

    BXY65M10W-2

    Product code

     

    Overview

    Installation of 100 standard instruments 4 digit
    Product quotationProduct consulting

    Product introduction


    1、 Overview
    This series of temperature controllers is an intelligent digital temperature measurement and control product that integrates temperature measurement, display, output, and control. This product is a fully electronic structure, with a front end equipped with an isolation film filled oil pressure resistance temperature sensor. It is converted by high-precision A/D, processed by a microprocessor, displayed on site, and outputs one analog signal and two switching signals.
    This intelligent temperature controller is flexible to use, easy to operate, easy to debug, and safe and reliable. Widely used in industries such as hydropower, tap water, petroleum, chemical, mechanical, hydraulic, etc., for on-site measurement, display, and control of fluid medium temperature
    2、 Characteristics
    Installation of 100 standard instruments
    4 digit LED digital tube display, ignoring value errors
    Two control point relays output 220V 3A
    ◆ 4-20mA standard signal output (optional)
    Control point on-site setting.
    ◆ Optional 24VDC 220VAC power supply



    3、 Technical parameters

    Mileage range P
    +
    Accuracy level+
    0.5% 4
    Overload capacity.
    200% P
    Temperature type+
    Gauge pressure+
    Stability+
    <0.1% per year+
    Power supply voltage P
    220VAC+
    Display method+
    056 "digital tube+
    Display range P
    -1999~9999+
    Environmental temperature+
    -20C-70C+
    Relative humidity+
    ≤ 80% 2
    Installation thread+
    G1/42
    material quality ρ
    Stainless steel+
    4、 Overall dimensions

    5、 Installation
    5.1 Mechanical connection:
    This controller can be directly installed through threads
    5.2 Electrical connections


    To prevent the impact of electromagnetic interference, the following precautions should be taken:
    ● Keep the line connection as short as possible
    ● Using shielded wires
    Try to avoid directly approaching the wiring of user devices or electrical and electronic devices that cause interference as much as possible
    If micro hoses are used for installation, the casing must be separately grounded
    6、 Setting functions
    Note: The switching point is determined by the configuration of the pull-in value and release value. When the pull-in value is greater than the release value, it is the upper limit alarm output (normally open function). When the pull-in value is less than the release value, it is the lower limit alarm output (normally closed function). The difference between the pull-in value and the release value is the return difference of the switching point.
    Example: To set the switch point 1 as the upper limit alarm output (normally open function) at 4 ℃ for suction and below 3.9 ℃ for disconnection,; Switch point 2 is the lower limit alarm output (normally closed function) that is disconnected at 10 degrees Celsius and sucked below 9.9 degrees Celsius:
    Enter menu: Settings
    AL1H=4.00 AL1L=3.95
    AL2H=9.95 AL1L=10.00
    Press the "SET" button
    ● Display "LOCK" (prompt for password input)
    Press the ▲ or ▼ keys to enter the password "1",
    Press the "SET" button to confirm
    Press the ▲ or ▼ keys to scroll up or down for menu selection (AL1H, AL1L, AL2H, AL2L, END)
    Press the "SET" button to enter the selected menu.
    Press the ▲ or ▼ keys to change the settings
    Press the "SET" button to confirm, and if necessary, use the ▲ or ▼ keys to select another option




    AL1AL1H This value is the pull-in value of switch 1 AL1L This value is the release value of switch 1
    AL2H is the pull-in value of switch 2, AL2L is the release value of switch 2
    END save exit ● If there is no key pressed for 30 seconds, the setting state will automatically exit, but the modified data will not be saved







    ?